Products / Ceramic heating elements / Flat heating elements
With the practical square base area of 12 mm x 12 mm, the type HT heating element is often used as a heated sample carrier in research and development applications. The good chemical resistance properties of the silicon nitride ceramics of the heating element allow such use even with cases of aggressive sample material. The hardness and wear resistance guarantee a long service life. Other application areas are microelectronics and medical engineering.
Parameter | Value |
---|---|
Dimensions | 12 x 12 x 3.1 mm |
Heated area | 12 x 12 x 3.1 mm |
Tmax | 500 °C |
* The actual power depends on resistance, temperature and voltage.
Parameter | Value |
---|---|
Article no. | FLE 100 589 |
Resistance @ 20 °C | 18,3 Ω ±25 % |
Nominal voltage | 24 V |
Nominal power @ 20 °C | 31,5 W* |